BGPVC - CHEVRON TRACTOR HYDRAULIC FLUID
- MSDS: BGPVC
- Manufacturer: CHEVRON ENVIRONMENTAL HEALTH CENTER INC
- Product Name: CHEVRON TRACTOR HYDRAULIC FLUID
- National Stock Number: 9150-01-177-9438
Product Identification
Product ID:CHEVRON TRACTOR HYDRAULIC FLUID
MSDS Date:10/23/1986
FSC:9150
NIIN:01-177-9438
MSDS Number: BGPVC
Responsible Party
RICHMOND, CA 94804-0054
US
Emergency Phone: 415-233-3737
Info Phone: 415-233-3737
Cage: 0AHD1
Contractor
Telephone: 800-582-3835
Cage: 0AHD1
Ingredients
DISTILLATES,SOLVENT REFINED HEAVY NAPHTHENIC
CAS: 64741-96-4
RTECS: PY8040000
Fraction By Weight: SEE #3%
OSHA PEL 5MG/M*3 (OIL MIST)
ACGIH TLV: 5MG/M*3 (OIL MIST)
DISTILLATES,HYDROTREATED HEAVY NAPHTHENIC
CAS: 64742-52-5
RTECS: PY8035000
Fraction By Weight: SEE #3%
OSHA PEL 5MG/M*3 (OIL MIST)
ACGIH TLV: 5MG/M*3 (OIL MIST)
DISTILLATES,SOLVENT-DEWAXED HEAVY PARAFFINIC (INGREDIENTS
CAS: 64742-65-0
RTECS: PY8038500
Fraction By Weight: 90%
OSHA PEL 5MG/M*3 (OIL MIST)
ACGIH TLV: 5MG/M*3 (OIL MIST)
PRODUCT IS COMPOSED OF EITHER 1,2, & 3,ABOVE,OR 5 & 6
RTECS: 9999999ZZ
HIGHLY REFINED BASE OIL
CAS: 72623-87-1
Fraction By Weight: SEE # 6%
OSHA PEL 5MG/M*3 (OIL MIST)
ACGIH TLV: 5MG/M*3 (OIL MIST)
HIGHLY REFINED BASE OIL (INGREDIENTS 5 & 6 = 90%)
CAS: 72623-85-9
Fraction By Weight: 90%
OSHA PEL 5MG/M*3 (OIL MIST)
ACGIH TLV: 5MG/M*3 (OIL MIST)
ADDITIVES INCLUDING INHIBITORS,ANTIWEAR AGENTS & ZINC ALKYL
CAS: 68649-43-3
Fraction By Weight: <10%
Hazards
Health Hazards Acute and
Chronic:EYES/SKIN:IRRITATION;INHALATION:IRRITATION,DISCOMFORT.NOT
EXPECTED TO BE ACUTELY TOXIC;INGESTION:NOT EXPECTED TO HAVE ACUTE
SYSTEMIC TOXICITY BY INGESTION.
Effects of Overexposure:MAY CAUSE EYE & SKIN IRRITATION AND RESPIRATORY
IRRITATION OR DISCOMFORT.
Medical Cond Aggravated by Exposure:NONE NOTED.
First Aid
First Aid:EYES:IMMEDIATELY FLUSH WITH WATER FOR 15 MINUTES.IF
IRRITATION PERSISTS,SEE DOCTOR;SKIN:WASH WITH SOAP &
WATER;INHALATION:REMOVE TO FRESH AIR.IF DISCOMFORT PERSISTS,SEE
DOCTOR;INGESTION:GIVE WATER OR MILK,SEE DOCTOR.
Fire Fighting
Flash Point Method:COC
Flash Point:374F(190C)
Extinguishing Media:CO*2,DRY CHEMICAL,FOAM,WATER FOG.
Fire Fighting Procedures:WEAR SCBA AND PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:NONE NOTED.
Accidental Release
Spill Release Procedures:ABSORB IN INERT MATERIAL AND PLACE IN
APPROPRIATE DISPOSAL CONTAINER.
Handling
Handling and Storage Precautions:DO NOT USE PRESSURE TO EMPTY DRUM OR
EXPLOSION MAY RESULT.DO NOT WELD,HEAT OR DRILL CONTAINER.RESIDUE
MAY IGNITE WITH EXPLOSIVE VIOLENCE IF HEATED.
Exposure Controls
Respiratory Protection:NONE NORMALLY NEEDED. NIOSH/MSHA APPROVED
RESPIRATORY IF TLV IS EXCEEDED.
Ventilation:MECHANICAL (GENERAL) VENTILATION TO KEEP BELOW TLV.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL SAFETY GOGGLES.
Other Protective Equipment:IMPERVIOUS PROTECTIVE CLOTHING.
Work Hygienic Practices:DO NOT GET IN EYES.AVOID PROLONGED CONTACT WITH
SKIN.WASH AFTER HANDLING.REMOVE & LAUNDER CONTAMINATED CLOTHING.
Supplemental Safety and Health
THIS IS NEW FORMULATION.FOR OLD FORMULATION SEE PNI A,SAME NSN.
Chemical Properties
HCC:V6
Spec Gravity:0.89
Viscosity:8 CST @ 212F
Solubility in Water:INSOLUBLE
Appearance and Odor:ORANGE LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAMES.
Hazardous Decomposition Products:CO,CO*2,OXIDES OF PHOSPHORUS.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL,STATE AND
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.